From source to storage · Enquiries across KenyaLet’s talk water: +254 743 731151 ↗
Phynetech commercial reverse osmosis machine range
Phynetech commercial reverse osmosis machine range. Supplier family photograph; selected capacity and frame may differ. Exact supplied configuration confirmed by quotation.

Commercial RO machines

Phynetech commercial RO machines — 250 to 1,500LPH

Phynetech RO machines for water-refilling businesses, hotels, schools and general institutional water supply. 250, 500, 1,000 and 1,500 litres/hour. Compare the listed specification and request supply or installation in Kenya.

Phynetech RO1000L: nominal 1,000 litres/hour. Feed analysis, recovery, pre-treatment, storage and site connections determine the final package. Equipment reference price; delivery, VAT treatment and installation confirmed by quotation.

Nominal permeate output
1,000 litres/hour
Daily sizing example
8,000 litres over eight productive hours, before derating and cleaning downtime
Exact pump, membranes and vessel quantities
Confirm on the written build specification

KSh 690,000.00 / unit

Equipment reference price where listed. Confirm availability, VAT treatment, delivery, installation and exact package contents in your written quotation.

Send your water report, daily demand, operating hours and location pin. Delivery and installation enquiries in all 47 counties.

Phynetech RO machines in Kenya: compare 250, 500, 1,000 and 1,500 litres/hour for water-refilling businesses, hotels, schools and general institutional water supply. Start with your water report and daily demand, then choose supply only or a quotation with installation.

Phynetech RO machines features and suitable uses

Choose this range for water-refilling businesses, hotels, schools and general institutional water supply. Match its feed-water limits and production rate to the intended application.

  • Commercial treatment train
  • High-pressure RO pumping
  • Capacity options for different daily requirements
Phynetech RO machines specifications
Capacity options 250 / 500 / 1,000 / 1,500LPH
Treatment configuration Supplier describes sand, carbon, softening, micron filtration, RO, UV and antiscalant dosing
Feed envelope Site-specific; full limits are not published for these listings

Compare capacity options and prices in Kenya

Model Specification Equipment price
RO250L Nominal permeate output: 250 litres/hour; Daily sizing example: 2,000 litres over eight productive hours, before derating and cleaning downtime; Exact pump, membranes and vessel quantities: Confirm on the written build specification KSh 264,500.00
RO500L Nominal permeate output: 500 litres/hour; Daily sizing example: 4,000 litres over eight productive hours, before derating and cleaning downtime; Exact pump, membranes and vessel quantities: Confirm on the written build specification KSh 379,500.00
RO1000L Nominal permeate output: 1,000 litres/hour; Daily sizing example: 8,000 litres over eight productive hours, before derating and cleaning downtime; Exact pump, membranes and vessel quantities: Confirm on the written build specification KSh 690,000.00
RO1500L Nominal permeate output: 1,500 litres/hour; Daily sizing example: 12,000 litres over eight productive hours, before derating and cleaning downtime; Exact pump, membranes and vessel quantities: Confirm on the written build specification KSh 977,500.00

Price, package contents and ordering

Choose a capacity below. Unpriced configurations require a written quotation.

The displayed equipment prices are reference prices for the listed specifications. Confirm VAT treatment, stock, transport, installation, tanks, additional pretreatment, consumables and warranty terms in your itemised quotation. A published reference price does not reserve stock or include every site connection.

Check compatibility before you buy

Confirm the exact membrane make, quantity, pump power, pretreatment vessel sizes, recovery, electrical supply and included accessories before placing an order. A supplier claim about free installation or certification is not a promise from our business. Hospital drinking-water use does not make these dialysis machines.

Rated production depends on temperature, inlet pressure, salinity and membrane condition. Do not size the complete installation using stage count or TDS alone. Share a recent physical, chemical and microbiological water report, intended operating hours, daily demand, power supply and location pin. Ask us to confirm product-water quality, recovery, reject-water arrangements and the commissioning tests.

Installation and support across Kenya

Request equipment delivery or reverse osmosis machine installation for your home, biashara or institution. Enquiries are welcome from all 47 counties; attendance, access, freight and service arrangements depend on your location. Our contact base is Kamulu, Nairobi. View RO capacities, prices and county coverage or choose your county.

Maintenance and ownership costs

Budget for feed and product-water tests, pre-filters, compatible replacement membranes, sanitisation, energy and reject-water handling. Record inlet/outlet pressures, permeate flow and conductivity during commissioning. These readings help identify a later drop in performance. Cleaning intervals follow the actual feed-water conditions and the supplied manufacturer manual, rather than a single promise for every site.

Documents and technical references

Use the current manufacturer instructions for the exact supplied model. Published catalogue information is a selection aid; confirm the bill of materials and product-water specification before payment.

Plan your Phynetech RO machines installation

For water-refilling businesses, hotels, schools and general institutional water supply, list the hours when water is needed and the amount you use in a normal day. Tell us whether the feed is county water, a borehole, stored rainwater or a mixture. Include existing tank sizes and the distance from the proposed treatment room to the point of use. We can then check the required output and identify which site items belong in your quotation.

Before accepting a quotation, compare the actual model and configuration shown above with the supplied equipment schedule. Check that the chosen pump suits your electrical supply and that you can obtain the specified replacement cartridges locally. Keep access clear around housings, valves and membrane vessels so routine maintenance does not require dismantling the whole installation.

At handover, ask for operating instructions, filter references, commissioning readings and the written warranty terms. Agree which checks your operator will do, and which work needs a technician. This gives you a practical basis for comparing ongoing costs as well as the purchase price.