
Industrial RO plants
Dayliff DRO8 industrial RO plants — 3,000 to 20,000LPH
Dayliff DRO8/5: nominal 5,000LPH permeate, 10,000LPH feed and 7.5/11kW low/medium brackish motor options. Engineered plant price on quotation.
- Nominal permeate output
- 5,000 litres/hour
- Nominal feed flow
- 10,000 litres/hour
- Low-brackish pump motor
- 7.5kW
- Medium-brackish pump motor
- 11kW
Request a quote / unit
Equipment reference price where listed. Confirm availability, VAT treatment, delivery, installation and exact package contents in your written quotation.
Send your water report, daily demand, operating hours and location pin. Delivery and installation enquiries in all 47 counties.
Dayliff DRO8 features and suitable uses
Choose this range for high-volume institutional supply, commercial processing and industrial water treatment. Match its feed-water limits and production rate to the intended application.
- Skid-mounted treatment plant
- Automatic controller and flushing
- Stainless-steel high-pressure pump
- Flow, pressure and conductivity instruments
| Feed TDS configurations | Low brackish up to 2,000ppm; medium brackish up to 5,000ppm |
|---|---|
| Water temperature | 5–35°C; design at 25°C |
| Minimum inlet pressure | 3 bar |
| Operating pressure | 4–20 bar, depending on feed quality |
| Recovery range | 35–75%, dependent on feed quality |
| Published normal salt rejection | 95–98%; not a drinking-water guarantee |
| Membrane format | 8-inch RO in pressure vessels |
Compare capacity options and prices in Kenya
| Model | Specification | Equipment price |
|---|---|---|
| DRO8/3 | Nominal permeate output: 3,000 litres/hour; Nominal feed flow: 6,000 litres/hour; Low-brackish pump motor: 4kW; Medium-brackish pump motor: 5.5kW | Request a quote |
| DRO8/4 | Nominal permeate output: 4,000 litres/hour; Nominal feed flow: 8,000 litres/hour; Low-brackish pump motor: 5.5kW; Medium-brackish pump motor: 7.5kW | Request a quote |
| DRO8/5 | Nominal permeate output: 5,000 litres/hour; Nominal feed flow: 10,000 litres/hour; Low-brackish pump motor: 7.5kW; Medium-brackish pump motor: 11kW | Request a quote |
| DRO8/8 | Nominal permeate output: 8,000 litres/hour; Nominal feed flow: 12,000 litres/hour; Low-brackish pump motor: 11kW; Medium-brackish pump motor: 15kW | Request a quote |
| DRO8/12 | Nominal permeate output: 12,000 litres/hour; Nominal feed flow: 18,000 litres/hour; Low-brackish pump motor: 11kW; Medium-brackish pump motor: 15kW | Request a quote |
| DRO8/16 | Nominal permeate output: 16,000 litres/hour; Nominal feed flow: 24,000 litres/hour; Low-brackish pump motor: 15kW; Medium-brackish pump motor: 18.5kW | Request a quote |
| DRO8/20 | Nominal permeate output: 20,000 litres/hour; Nominal feed flow: 30,000 litres/hour; Low-brackish pump motor: 18.5kW; Medium-brackish pump motor: 22kW | Request a quote |
Price, package contents and ordering
Choose a capacity below. Unpriced configurations require a written quotation.
The displayed equipment prices are reference prices for the listed specifications. Confirm VAT treatment, stock, transport, installation, tanks, additional pretreatment, consumables and warranty terms in your itemised quotation. A published reference price does not reserve stock or include every site connection.
Check compatibility before you buy
A process-water specification may need polishing, remineralisation or extra disinfection. These are standard brackish-water configurations; seawater, dialysis and ultrapure applications require separate engineered systems.
Rated production depends on temperature, inlet pressure, salinity and membrane condition. Do not size the complete installation using stage count or TDS alone. Share a recent physical, chemical and microbiological water report, intended operating hours, daily demand, power supply and location pin. Ask us to confirm product-water quality, recovery, reject-water arrangements and the commissioning tests.
Installation and support across Kenya
Request equipment delivery or reverse osmosis machine installation for your home, biashara or institution. Enquiries are welcome from all 47 counties; attendance, access, freight and service arrangements depend on your location. Our contact base is Kamulu, Nairobi. View RO capacities, prices and county coverage or choose your county.
Maintenance and ownership costs
Budget for feed and product-water tests, pre-filters, compatible replacement membranes, sanitisation, energy and reject-water handling. Record inlet/outlet pressures, permeate flow and conductivity during commissioning. These readings help identify a later drop in performance. Cleaning intervals follow the actual feed-water conditions and the supplied manufacturer manual, rather than a single promise for every site.
Documents and technical references
- Dayliff product catalogue
- DRO8/3 original specification
- DRO8/4 original specification
- DRO8/5 original specification
- DRO8/8 original specification
- DRO8/12 original specification
- DRO8/16 original specification
- DRO8/20 original specification
Use the current manufacturer instructions for the exact supplied model. Published catalogue information is a selection aid; confirm the bill of materials and product-water specification before payment.
Plan your Dayliff DRO8 installation
For high-volume institutional supply, commercial processing and industrial water treatment, list the hours when water is needed and the amount you use in a normal day. Tell us whether the feed is county water, a borehole, stored rainwater or a mixture. Include existing tank sizes and the distance from the proposed treatment room to the point of use. We can then check the required output and identify which site items belong in your quotation.
Before accepting a quotation, compare the actual model and configuration shown above with the supplied equipment schedule. Check that the chosen pump suits your electrical supply and that you can obtain the specified replacement cartridges locally. Keep access clear around housings, valves and membrane vessels so routine maintenance does not require dismantling the whole installation.
At handover, ask for operating instructions, filter references, commissioning readings and the written warranty terms. Agree which checks your operator will do, and which work needs a technician. This gives you a practical basis for comparing ongoing costs as well as the purchase price.